  electromagnetic coupling rfid system v600 1 electromagnetic coupling rfid system v600 non-contact data communications system ? new compact, slim controller with two input channels added to the lineup.  superior environmental resistance.  heat-resistant data carrier available (150 c max.).  large memory capacity of 8 kbytes for built-in-battery data car- riers and 254 bytes for battery-less data carriers.  built-in-battery data carriers have a battery life detecting func- tion.  data of battery-less data carriers with small memory capacity can be overwritten 300,000 times at normal temperatures.  thin, compact, and low-cost data carriers are available.  transmission distance of 100 mm max.  ce marking/fcc approvals. ordering information data carriers item model specifications/design/memory capacity large memory capacity built-in-battery data car- riers v600-d8kr12 rectangular compact 65 40 15 mm 8 kbytes v600-d8kr13 thin rectangular 86 54 10.3 mm v600-d8kr04 intermediate-range rectangular 86 54 20 mm battery-less data carri- ers v600-d8kf04 intermediate-range rectangular 86 54 20 mm replaceable-battery data carriers v600-d2kr16 compact 65 40 5 mm 2 kbytes small memory capacity battery-less data carri- ers v600-d23p71 ultrathin card-type 86 54 1.5 mm 254 bytes v600-d23p72 thin half-size card-type 50 34 1.5 mm v600-d23p66n rectangular 34 34 3.5 mm v600-d23p66sp rectangular package with pfa 95 36.5 6.5 mm v600-d23p61 rectangular compact 32 24 6 mm v600-d23p53 round super-compact 8 dia. 5 mm v600-d23p54 round compact 12 dia. 6 mm v600-d23p55 round super-compact 8 dia. 5 mm q124-e1-03.fm page 1 tuesday, may 30, 2006 5:22 pm
2 electromagnetic coupling rfid system v600 r/w heads id controllers item model specifications/design rectangular type v600-h07 (0.5 m) dimensions: 100 100 30 mm 0.5-m cable v600-h07 (2 m) 2-m cable v600-h07 (5 m) 5-m cable v600-h07 (10 m) 10-m cable v600-h11 (0.5 m) dimensions: 53 40 23 mm 0.5-m cable v600-h11-r (0.5 m) 0.5-m cable v600-h11 (2 m) 2-m cable v600-h11 (5 m) 5-m cable v600-h11 (10 m) 10-m cable cylinder type v600-h51 (0.5 m) dimensions: 22 dia. 80 mm 0.5-m cable v600-h51 (2 m) 2-m cable v600-h51 (5 m) 5-m cable v600-h51 (10 m) 10-m cable v600-h52 (0.5 m) dimensions: 22 dia. 85 mm 0.5-m cable v600-h52 (2 m) 2-m cable v600-h52 (5 m) 5-m cable v600-h52 (10 m) 10-m cable separate-amplifier type amplifier section v600-ha51 (2 m) 73.8 22.6 36.5 mm, with 2-m cable v600-ha51 (5 m) 73.8 22.6 36.5 mm, with 5-m cable v600-ha51 (10 m) 73.8 22.6 36.5 mm, with 10-m cable sensor section v600-hs51 12 dia. 35 mm deep, with 2-m cable v600-hs61 30.5 18 10 mm, with a 2-m cable item model specifications/design dc power supply v600-ca5d02 24 vdc two r/w head channels 105 90 65 mm host rs-232c, rs-422, and rs-485 interfaces v600-cd1d-v3 24 vdc single r/w head connect- able 115 68 80 mm rs-232c host interface v600-cm1d 24-vdc, 5-vdc 2-system input single r/w head connect- able board type dc power supply v600-idsc02 24 vdc rs-232c interface two r/w heads connect- able v600-idsc04 four r/w heads connect- able p o w e r power dc 2 4 v dc24v in p u t input m a o n maon n o. no. x 10 x10 h e a d 1 head1 h e a d 2 head2 ou t out in in 1 2 3 4 5 1 2 3 t e st test o n on p o w e r power d c 2 4v dc24v in p u t input m a on maon n o . no. x1 0 x10 h e ad 1 head1 h e a d 2 head2 h e a d 1 head1 h e a d 2 head2 m ao n mao n n o. no. x 1 0 x10 o u t out in in 1 2 3 4 5 1 2 3 t e st test o n on t e st test o n on 124e103.p2tm30200522pm
electromagnetic coupling rfid system v600 3 accessories (order separately) rs-232c cables (order separately) connectors for id controllers (one set per unit) item model specifications/design extension cable for r/w heads v600-a45 standard cable non-water-resistant connectors 3-m cable V600-A44 5-m cable v600-a40 10-m cable v600-a41 20-m cable v600-a42 30-m cable v600-a56 robotic cable non-water-resistant connectors 3-m cable v600-a55 5-m cable v600-a50 10-m cable v600-a51 20-m cable v600-a52 30-m cable holder v600-a81 for the v600-d2kr16 *mount with m3 flat countersunk head screws (at least two). v600-a84 for the v600-d23p71/d23p72 ultrasonic deposition can be used on the plastic container. attachment v600-a86 for the v600-d23p66n model cable length compatible id controllers xw2z-200s 2 m xw2z-500s 5 m v600-cd1d-v3 v600-cm1d model name compatible id controllers xm2a-0901 connector plug xm2s-0911 connector hood mc1.5/5-stf-3.5 (made by phoenix contact) rs-422/ rs-485 communica- tions connector v600-ca5d02 v600-cd1d-v3 v600-cm1d q124-e1-03.fm page 3 tuesday, may 30, 2006 5:22 pm
4 electromagnetic coupling rfid system v600 specifications battery-less data carriers with small memory capacity note: the 150 c heat resistance was confirmed by leaving the unit at 150 c for 1,000 continuous hours, and by a thermal shock test consisting of 1,000 ? 10 c/150 c cycles of 30 min each. no defect was found among the 22 test samples. shape ultrathin card-type ultrathin half-size card-type rectangular compact chemical- resistant rectangular compact round super- compact round compact round super- compact item model v600- d23p71 v600- d23p72 v600- d23p66n v600- d23p66sp v600- d23p61 v600- d23p53 v600- d23p54 v600- d23p55 memory capacity 254 bytes memory type eeprom (non-volatile memory) transmission distance refer to ?transmission distance specifications for battery-less data carriers with small memory capacity? on page 10. data retention time (after writing data) 10 years 10 years ( ? 40 to 110 c) 1 year ( ? 40 to 150 c) 10 years 10 years ( ? 40 to 110 c) 1 year ( ? 40 to 150 c) number of overwrites (per address) (refer to separate item for ambient temperature) up to 0 c 800,000 times up to 25 c 400,000 times up to 60 c 300,000 times up to 85 c 100,000 times transmission error detection 16-bit crc in both directions (crc: cyclic redundancy check) ambient temperature for data storage ? 20 to 110 c ?4 0 to 150 c (see note.) ? 40 to 110 c ? 40 to 85 c ?4 0 to 150 c (see note.) for reading/ writing ? 10 to 70 c ? 20 to 85 c ? 20 to 70 c ? 25 to 70 c ? 25 to 85 c storage temperature ? 20 to 110 c ?4 0 to 150 c (see note.) ? 40 to 110 c ? 40 to 85 c ?4 0 to 150 c (see note.) ambient humidity operating: 35% to 95% degree of protection iec 60529: ip67 iec 60529: ip68 iec 60529: ip67 iec 60529: ip67 iec 60529: ip67 vibration resistance (destruction) 10 to 2,000 hz, 3.0-mm double amplitude, 300 m/s 2 acceleration for 30 min each in 3 directions (90 min total) 10 to 2,000 hz, 1.5-mm double amplitude, 150 m/s 2 accel- eration 10 times each in 3 directions (15 min) 10 to 2,000 hz, 3.0-mm double amplitude, 300 m/s 2 accel- eration for 30 min each in 3 directions (90 min total) 10 to 2,000 hz, 1.5-mm double amplitude, 150 m/s 2 accel- eration 10 times each in 3 directions (15 min) shock resistance (destruction) 1,000 m/s 2 3 times each in 3 directions (18 times total) 500 m/s 2 3 times each in 3 directions (18 times total) 1,000 m/s 2 3 times each in 3 directions (18 times total) 500 m/s 2 3 times each in 3 directions (18 times total) weight approx. 15 g approx. 5 g approx 6.5 g approx. 19 g approx. 5.8 g approx. 0.4 g approx. 1.0 g approx. 0.6 g q124-e1-03.fm page 4 tuesday, may 30, 2006 5:22 pm
electromagnetic coupling rfid system v600 5 data carriers with large memory capacity note: 1. a low battery detection function is built-in. 2. the battery life is applicable for batteries used at a temperature of 25 c. refer to ?temperature and battery life? on page 22 for details on the relationship between temperature and battery life. the lithium battery is commercially available (cr2016). 3. the data carrier is dustproof when the provided battery replacement cover seal is used. 4. data holding time: 10 years shape built-in-battery battery-less replaceable-battery rectangular compact rectangular thin rectangular intermediate range rectangular intermediate range rectangular compact with replaceable battery item model v600-d8kr12 v600-d8kr13 v600-d8kr04 v600-d8kf04 v600-d2kr16 memory capacity 8 kb 2 kb memory type sram (volatile memory) feram (nonvolatile memory) sram (volatile memory) transmission distance refer to ?transmission distance specifications for data carriers with large memory capacity (built-in-battery/battery- less/replaceable-battery)? on page 15 battery life (see note 1.) refer to ?battery life? on page 22 --- (see note 4.) 2 years (at 25 c) (see note 2.) number of reads/writes unlimited 1,000 million unlimited (does not affect battery life) transmission error detection 16-bit crc in both directions (crc: cyclic redundancy check) ambient temperature for data storage ? 40 to 70 c ? 15 to 70 c for reading/ writing ? 25 to 70 c 0 to 50 c storage temperature ? 40 to 70 c ? 15 to 70 c ambient humidity 35% to 95% 35% to 85% storage humidity 35% to 95% degree of protection iec 60529: ip67 iec 60529: ip50 (dust- proof) (see note 3.) vibration resistance (destruction) 10 to 500 hz, 1.0-mm single amplitude, 150 m/s 2 acceleration with 3 sweeps of 11 min each in x, y, and z directions 10 to 150 hz, 0.75-mm single amplitude, 100- m/s 2 acceleration for 30 min each in x, y, and z directions shock resistance (destruction) 1,000 m/s 2 3 times each in x, y, and z directions (18 times total) 500 m/s 2 3 times each in x, y, and z direc- tions (18 times total) 300 m/s 2 3 times each in x, y, and z direc- tions (18 times total) weight approx. 70 g approx. 160 g approx. 150 g approx. 15 g q124-e1-03.fm page 5 tuesday, may 30, 2006 5:22 pm
6 electromagnetic coupling rfid system v600 read/write (r/w) heads with built-in amplifier note: 1. extension cables are also available. the maximum cable length is 30.5 m for the v600-h07 and 50.5 m for the v600-h11/h51/h52. 2. the connectors are not water-resistant. model v600-h07 v600-h11/h11-r v600-h51 v600-h52 item oscillation frequency 530 khz ambient temperature ? 25 to 70 c ? 10 to 60 c storage temperature ? 40 to 85 c ? 25 to 75 c ambient humidity 35% to 95% storage humidity 35% to 95% insulation resistance 50 m ? min. (at 500 vdc) between cable terminals and case dielectric strength 1,000 vac, 50/60 hz for 1 min between cable terminals and case (leakage current: 1 ma max.) degree of protection iec 60529: ip67 vibration resistance (destruction) 10 to 500 hz, 1.0-mm single amplitude, 150 m/s 2 acceleration with 3 sweeps of 11 min each in x, y, and z directions shock resistance destruction: 500 m/s 2 3 times each in x, y, and z directions (18 times total) cable length (see note 1.) standard lengths of 0.5 m, 2 m, 5 m, and 10 m. wireless transmission error detection 16-bit crc in both directions (crc: cyclic redundancy check) indicators power: green; transmission: orange weight approx. 1 kg (with 10-m cable) approx. 650 g (with 10-m cable) q124-e1-03.fm page 6 tuesday, may 30, 2006 5:22 pm
electromagnetic coupling rfid system v600 7 read/write (r/w) heads with separate amplifier note: 1. extension cables are also available. the maximum cable length is 50 m for the v600-ha51. extension cables are not available for the v600-hs51/hs61. 2. the connectors are not water-resistant. model sensor section amplifier section item v600-hs51 v600-hs61 v600-ha51 oscillation frequency 530 khz --- ambient temperature ? 10 to 60 c storage temperature ? 25 to 75 c ambient humidity 35% to 95% insulation resistance 50 m ? min. (at 500 vdc) between cable terminals and case dielectric strength 1,000 vac 50/60 hz for 1 min between cable terminals and case (leakage current: 1 ma max.) degree of protection iec 60529: ip67 iec 60529: ip66 vibration resistance (destruction) 10 to 2,000 hz, 1.5-mm single amplitude, 300 m/s 2 accel- eration with 2 sweeps of 15 min each in 3 directions installed in panel 10 to 2,000 hz, 1.5-mm single am- plitude, 300-m/s 2 acceleration with 2 sweeps of 11 min each in 3 direc- tions din track installa- tion 10 to 500 hz, 1.0-mm single ampli- tude, 150-m/s 2 acceleration with 3 sweeps of 11 min each in 3 direc- tions shock resistance (destruction) 1,000 m/s 2 3 times each in 3 directions (18 times total) 500 m/s 2 3 times each in 3 directions (18 times total) cable length sensor to amplifier 2 m (fixed) --- amplifier to controller --- standard lengths of 2 m, 5 m, and 10 m (see note 1.) wireless transmission error detection 16-bit crc in both directions (crc: cyclic redundancy check) indicators --- power: green; transmission: orange weight approx. 70 g (with 2-m cable) approx. 650 g (with 10-m cable) q124-e1-03.fm page 7 tuesday, may 30, 2006 5:22 pm
8 electromagnetic coupling rfid system v600 id controllers series v600 series item model v600-ca5d02 v600-cd1d-v3 v600-cm1d host interface rs-232c, rs-422, rs-485 rs-232c possible number of r/w heads 21 power supply voltage 24 vdc 24 vdc 24 vdc, 5 vdc acceptable power supply voltage 20.4 to 26.4 vdc 20.4 to 26.4 vdc 20.4 to 26.4 vdc 4.5 to 5.5 vdc power consumption 15 w max. 7.2 w max. 24 vdc: 7.2 w max. 5 vdc: 1.5 w max. insulation resistance 50 m ? min. (at 500 vdc) between power terminals and case, between i/o terminals and case, or between the power supply terminals and i/o terminals dielectric strength 1,000 vac, 50/60 hz for 1 min be- tween the points listed above; leakage current: 10 ma max. 1,000 vac, 50/60 hz for 1 min between the points listed above; leakage current: 10 ma max. noise immunity 1,500-v (p-p) pulses of 100-ns to 1- s pulse width with a 1-ns rise time vibration resistance destruction --- 10 to 150 hz, 0.3-mm double amplitude for 32 min each in x, y, and z direc- tions malfunction 10 to 150 hz, 0.2-mm double ampli- tude, 15 m/s 2 acceleration 10 times for 8 min each in 3 directions 10 to 150 hz, 0.2-mm double amplitude for 32 min each in x, y, and z direc- tions shock resistance destruction --- destruction: 200 m/s 2 3 times each in x, y, and z directions (18 times total) malfunction 150 m/s 2 3 times each in x, y, and z directions (18 times total) --- ambient temperature ? 10 to 55 c0 t o 5 0 c ambient humidity 35% to 85% (with no condensation) operating conditions no corrosive gases storage temperature ? 25 to 65 c ? 15 to 70 c memory back-up a capacitor backs up the most recent error data and statistical error data for up to 20 days (at 25 c) after a power interruption. memory backup is not available. error details, however, can be read from the personal computer when the power is turned on. diagnostic functions checks for cpu errors, memory errors, power interruptions, and transmission errors ground ground to 100 ? or less. degree of protection iec 60529: ip30 (panel mounted) weight approx. 300 g approx 360 g approx. 180 g q124-e1-03.fm page 8 tuesday, may 30, 2006 5:22 pm
electromagnetic coupling rfid system v600 9 v600-idsc series v600-idsc series model item v600-idsc02 v600-idsc04 host interface rs-232c possible number of r/w heads 24 power supply voltage 24 vdc acceptable power supply voltage 19.2 to 28.8 vdc power consumption 50 w max. insulation resistance 20 m ? min. (at 500 vdc) between power supply terminals and frame ground terminals dielectric strength 1,000 vac, 50/60 hz for 1 min between power supply terminals and frame ground terminals with a de- tected current of10 ma max. vibration resistance 10 to 50 hz, 0.075-mm amplitude, 57 to 150 hz, 9.8 m/s 2 acceleration for 10 sweeps each in x, y, and z directions shock resistance 147 m/s 2 3 times each in x, y, and z directions ambient temperature 0 to 55 c (with no icing) ambient humidity 10% to 90% (with no condensation) storage temperature ? 20 to 75 c (with no icing) storage humidity 10% to 90% (with no condensation) ground ground to 100 ? or less. ground to 100 ? or less. construction installed in panel installed in panel weight approx. 700 g approx. 800 g p o w e r po wer d c 2 4v dc24v in p u t input m a o n maon no . no. x1 0 x10 h e a d 1 head1 h e a d 2 head2 o u t out in in 1 2 3 4 5 1 2 3 t e s t test o n on p o w e r power d c 2 4v dc24v in p u t input m ao n maon n o. no. x 1 0 x10 h e a d 1 head1 h e a d 2 head2 h e a d 1 head1 h e a d 2 head2 m a o n maon n o . no . x 10 x10 o u t out in in 1 2 3 4 5 1 2 3 t e s t test o n on te st test o n on q124-e1-03.fm page 9 tuesday, may 30, 2006 5:22 pm
10 electromagnetic coupling rfid system v600 transmission distance specifications for battery-less data carriers with small memory capacity note: 1. the transmission distance/transmission time priority mode setting can be made using the lower-level transmission mode setting s witch or memory switch only with a serial-interface controller or id sensor unit. 2. with parallel-interface controllers, the mode setting is always transmission distance priority. 3. the specifications take fluctuations in ambient temperature and slight differences between products into account. recommended combinations installation controller mode transmission distance condition for dc and r/w head installation data carrier r/w head v600-d23p71 v600-h07 stationary read dis- tance irrelevant 10 to 70 mm (max. axi- al offset 10 mm) these data carriers are for installa- tion on non-metallic surfaces only. data transmission will be impossi- ble if the dc is installed directly on a metal surface. refer to the v600 r/w heads and eeprom data carriers operation manual (cat. no. z128) for details. write dis- tance moving read dis- tance 30 to 60 mm (max. axi- al offset 10 mm) write dis- tance v600-h11/-h11-r stationary read dis- tance irrelevant 5 to 40 mm (max. axial offset 10 mm) write dis- tance moving read dis- tance 15 to 40 mm (max. axi- al offset 10 mm) write dis- tance v600-d23p72 v600-h07 stationary read dis- tance irrelevant 10 to 50 mm (max. axi- al offset 10 mm) write dis- tance moving read dis- tance 30 to 40 mm (max. axi- al offset 10 mm) write dis- tance v600-h11/-h11-r stationary read dis- tance irrelevant 5 to 30 mm (max. axial offset 10 mm) write dis- tance moving read dis- tance 15 to 30 mm (max. axi- al offset 10 mm) write dis- tance v600-d23p71/72 data carrier (resin, plastic, wood, etc.) non-metallic r/w head iron q124-e1-03.fm page 10 tuesday, may 30, 2006 5:22 pm
electromagnetic coupling rfid system v600 11 note: 1. the transmission distance/transmission time priority mode setting can be made using the lower-level transmission mode setting s witch or memory switch only with a serial-interface controller or id sensor unit. 2. with parallel-interface controllers, the mode setting is always transmission distance priority. 3. the specifications take fluctuations in ambient temperature and slight differences between products into account. recommended combinations installation controller mode transmission distance condition for dc and r/w head installation data carrier r/w head v600-d23p66n v600-h07 stationary read dis- tance transmission distance priority 5 to 45 mm (max. axial offset 10 mm) data transmission will be impossi- ble if the dc is installed directly on a metal surface. refer to the v600 r/w heads and eeprom data carriers operation manual (cat. no. z128) for details. transmission time priority 5 to 35 mm (max. axial offset 10 mm) write dis- tance irrelevant 5 to 35 mm (max. axial offset 10 mm) moving read dis- tance transmission distance priority 25 to 40 mm (max. axi- al offset 10 mm) transmission time priority 25 to 30 mm (max. axi- al offset 10 mm) write dis- tance irrelevant 25 to 30 mm (max. axi- al offset 10 mm) v600-h11/-h11-r stationary read dis- tance transmission distance priority 5 to 30 mm (max. axial offset 10 mm) transmission time priority 5 to 25 mm (max. axial offset 10 mm) write dis- tance irrelevant 5 to 25 mm (max. axial offset 10 mm) moving read dis- tance transmission distance priority 15 to 25 mm (max. axi- al offset 10 mm) transmission time priority 15 to 20 mm (max. axi- al offset 10 mm) write dis- tance irrelevant 15 to 20 mm (max. axi- al offset 10 mm) v600- d23p66sp v600-h07 stationary read dis- tance transmission distance priority 5 to 40 mm (max. axial offset 10 mm) transmission time priority 5 to 30 mm (max. axial offset 10 mm) write dis- tance irrelevant 5 to 30 mm (max. axial offset 10 mm) moving read dis- tance transmission distance priority 20 to 40 mm (max. axi- al offset 10 mm) transmission time priority 20 to 30 mm (max. axi- al offset 10 mm) write dis- tance irrelevant 20 to 30 mm (max. axi- al offset 10 mm) v600-h11/-h11-r stationary read dis- tance transmission distance priority 5 to 25 mm (max. axial offset 10 mm) transmission time priority 5 to 20 mm (max. axial offset 10 mm) write dis- tance irrelevant 5 to 20 mm (max. axial offset 10 mm) moving read dis- tance transmission distance priority 10 to 25 mm (max. axi- al offset 10 mm) transmission time priority 10 to 20 mm (max. axi- al offset 10 mm) write dis- tance irrelevant 10 to 20 mm (max. axi- al offset 10 mm) (resin, plastic, wood, etc.) non-metallic data carrier r/w head iron q124-e1-03.fm page 11 tuesday, may 30, 2006 5:22 pm
12 electromagnetic coupling rfid system v600 note: 1. the transmission distance/transmission time priority mode setting can be made using the lower-level transmission mode setting s witch or memory switch only with a serial-interface controller or id sensor unit. 2. with parallel-interface controllers, the mode setting is always transmission distance priority. 3. the specifications take fluctuations in ambient temperature and slight differences between products into account. recommended combinations installation controller mode transmission distance condition for dc and r/w head installation data carrier r/w head v600-d23p61 v600-h11/-h11-r stationary read dis- tance transmission distance priority 2 to 19 mm (max. axial offset 10 mm) these data carriers can be in- stalled on metallic surfaces. the listed transmission distances also apply for installation on non- metallic surfaces. refer to the v600 r/w heads and eeprom data carriers operation manual (cat. no. z128) for details. transmission time priority 2 to 16 mm (max. axial offset 10 mm) write dis- tance irrelevant 2 to 16 mm (max. axial offset 10 mm) moving read dis- tance transmission distance priority 12 to 19 mm (max. axi- al offset 10 mm) transmission time priority 12 to 16 mm (max. axi- al offset 10 mm) write dis- tance irrelevant 12 to 16 mm (max. axi- al offset 10 mm) v600-h51 stationary read dis- tance transmission distance priority 1 to 16 mm (max. axial offset 10 mm) transmission time priority 1 to 14 mm (max. axial offset 10 mm) write dis- tance irrelevant 1 to 14 mm (max. axial offset 10 mm) moving read dis- tance transmission distance priority 7 to 16 mm (max. axial offset 10 mm) transmission time priority 7 to 14 mm (max. axial offset 10 mm) write dis- tance irrelevant 7 to 14 mm (max. axial offset 10 mm) v600-d23p61 data carrier iron iron (sc, ss) iron (sc, ss) v600-d23p61 data carrier v600-h11 r/w head iron v600-h51 r/w head q124-e1-03.fm page 12 tuesday, may 30, 2006 5:22 pm
electromagnetic coupling rfid system v600 13 note: 1. the transmission distance/transmission time priority mode setting can be made using the lower-level transmission mode setting s witch or memory switch only with a serial-interface controller or id sensor unit. 2. with parallel-interface controllers, the mode setting is always transmission distance priority. 3. the specifications take fluctuations in ambient temperature and slight differences between products into account. 4. this is the transmission distance when using the v600-hs @ 1 and v600-ha51 combination. recommended combinations installation controller mode transmission distance condition for dc and r/w head installation data carrier r/w head v600-d23p53 v600-hs51 (see note 4.) stationary read dis- tance transmission distance priority 0.5 to 4.0 mm (max. axial offset 2 mm) 0.5 to 4.5 mm (max. axial offset 1 mm) these data carriers are for flush mounting in metallic bases only. the listed transmission distances also apply for installation on non- metallic surfaces. refer to the v600 r/w heads and eeprom data carriers operation manual (cat. no. z128) for details. transmission time priority 0.5 to 3.0 mm (max. axial offset 2 mm) 0.5 to 3.5 mm (max. axial offset 1 mm) write dis- tance irrelevant 0.5 to 3.0 mm (max. axial offset 2 mm) 0.5 to 3.5 mm (max. axial offset 1 mm) v600-hs61 (see note 4.) stationary read dis- tance transmission distance priority 0.5 to 4.0 mm (max. axial offset 2 mm) 0.5 to 4.5 mm (max. axial offset 1 mm) transmission time priority 0.5 to 3.0 mm (max. axial offset 2 mm) 0.5 to 3.5 mm (max. axial offset 1 mm) write dis- tance irrelevant 0.5 to 3.0 mm (max. axial offset 2 mm) 0.5 to 3.5 mm (max. axial offset 1 mm) v600-h52 stationary read dis- tance transmission distance priority 0.5 to 4.0 mm (max. axial offset 2 mm) 0.5 to 4.5 mm (max. axial offset 1 mm) transmission time priority 0.5 to 3.0 mm (max. axial offset 2 mm) 0.5 to 3.5 mm (max. axial offset 1 mm) write dis- tance irrelevant 0.5 to 3.0 mm (max. axial offset 2 mm) 0.5 to 3.5 mm (max. axial offset 1 mm) v600-d23p54 v600-hs51 (see note 4.) stationary read dis- tance transmission distance priority 0.5 to 6.0 mm (max. axial offset 2 mm) 0.5 to 6.5 mm (max. axial offset 1 mm) transmission time priority 0.5 to 5.5 mm (max. axial offset 2 mm) 0.5 to 6.0 mm (max. axial offset 1 mm) write dis- tance irrelevant 0.5 to 5.0 mm (max. axial offset 2 mm) 0.5 to 5.5 mm (max. axial offset 1 mm) v600-hs61 (see note 4.) stationary read dis- tance transmission distance priority 0.5 to 6.5 mm (max. axial offset 2 mm) 0.5 to 7.0 mm (max. axial offset 1 mm) transmission time priority 0.5 to 5.5 mm (max. axial offset 2 mm) 0.5 to 6.0 mm (max. axial offset 1 mm) write dis- tance irrelevant 0.5 to 5.5 mm (max. axial offset 2 mm) 0.5 to 6.0 mm (max. axial offset 1 mm) v600-h52 stationary read dis- tance transmission distance priority 0.5 to 6.5 mm (max. axial offset 2 mm) 0.5 to 7.0 mm (max. axial offset 1 mm) transmission time priority 0.5 to 5.5 mm (max. axial offset 2 mm) 0.5 to 6.0 mm (max. axial offset 1 mm) write dis- tance irrelevant 0.5 to 5.5 mm (max. axial offset 2 mm) 0.5 to 6.0 mm (max. axial offset 1 mm) iron (sc, ss) v600-d23p53/54 data carrier v600-hs61 r/w head iron iron(sc, ss) v600-d23p53/54 data carrier v600-hs51 r/w head iron iron ( sc, ss ) v600-d23p53/54 data carrier v600-h52 r/w head iron q124-e1-03.fm page 13 tuesday, may 30, 2006 5:22 pm
14 electromagnetic coupling rfid system v600 note: 1. the transmission distance/transmission time priority mode setting can be made using the lower-level transmission mode setting s witch or memory switch only with a serial-interface controller or id sensor unit. 2. with parallel-interface controllers, the mode setting is always transmission distance priority. 3. the specifications take fluctuations in ambient temperature and slight differences between products into account. 4. this is the transmission distance when using the v600-hs @ 1 and v600-ha51 combination. recommended combinations installation controller mode transmission distance condition for dc and r/w head installation data carrier r/w head v600-d23p55 v600-hs51 (see note 4.) stationary read dis- tance transmission distance priority 0.5 to 6.5 mm (max. axial offset 2 mm) these data carriers are for flush mounting in non-metallic bases only. the transmission distance decreas- es considerably when flush mount- ed in non-metallic bases. refer to the v600 r/w heads and eeprom data carriers operation manual (cat. no. z128) for details. transmission time priority 0.5 to 6.0 mm (max. axial offset 2 mm) write dis- tance transmission distance priority 0.5 to 6.5 mm (max. axial offset 2 mm) transmission time priority 0.5 to 6.0 mm (max. axial offset 2 mm) v600-hs61 (see note 4.) stationary read dis- tance transmission distance priority 0.5 to 7.0 mm (max. axial offset 2 mm) transmission time priority 0.5 to 6.0 mm (max. axial offset 2 mm) write dis- tance transmission distance priority 0.5 to 7.0 mm (max. axial offset 2 mm) transmission time priority 0.5 to 6.0 mm (max. axial offset 2 mm) v600-h52 stationary read dis- tance transmission distance priority 0.5 to 9.0 mm (max. axial offset 2 mm) transmission time priority 0.5 to 8.5 mm (max. axial offset 2 mm) write dis- tance transmission distance priority 0.5 to 8.5 mm (max. axial offset 2 mm) transmission time priority 0.5 to 8.5 mm (max. axial offset 2 mm) v600-d23p55 data carrier v600-hs61 r/w head iron v600-hs51 r/w head iron v600-h52 r/w head iron (resin, plastic, wood, etc.) non-metallic v600-d23p55 data carrier (resin, plastic, wood, etc.) non-metallic v600-d23p55 data carrier (resin, plastic, wood, etc.) non-metallic q124-e1-03.fm page 14 tuesday, may 30, 2006 5:22 pm
electromagnetic coupling rfid system v600 15 transmission distance specifications for data carriers with large memory capacity (built-in-battery/battery-less/replaceable-battery) recommended combinations installation controller mode transmission distance condition for dc and r/w head installation data carrier r/w head v600-d8kr12 v600-h07 stationary flush-mount- ed in metal irrelevant 10 to 50 mm (max. axi- al offset 10 mm) the listed transmission distances also apply for installation on non- metallic surfaces. refer to the v600 r/w heads and sram data carri- ers operation manual (cat. no. z127) for details. surface- mounted on metal 10 to 60 mm (max. axi- al offset 10 mm) moving flush-mount- ed in metal 25 to 50 mm (max. axi- al offset 10 mm) surface- mounted on metal 25 to 60 mm (max. axi- al offset 10 mm) v600-h11 stationary flush-mount- ed in metal irrelevant 5 to 40 mm (max. axial offset 10 mm) surface- mounted on metal 5 to 45 mm (max. axial offset 10 mm) moving flush-mount- ed in metal 25 to 40 mm (max. axi- al offset 10 mm) surface- mounted on metal 25 to 45 mm (max. axi- al offset 10 mm) v600-d8kr13 v600-h07 stationary flush-mount- ed in metal irrelevant 10 to 30 mm (max. axi- al offset 10 mm) surface- mounted on metal 10 to 35 mm (max. axi- al offset 10 mm) moving flush-mount- ed in metal 20 to 30 mm (max. axi- al offset 10 mm) surface- mounted on metal 20 to 35 mm (max. axi- al offset 10 mm) v600-h11 stationary flush-mount- ed in metal irrelevant 10 to 30 mm (max. axi- al offset 10 mm) surface- mounted on metal moving flush-mount- ed in metal 15 to 30 mm (max. axi- al offset 10 mm) surface- mounted on metal data carrie r surface-mounted on metal data carrier flush-mounted in metal r/w head metal metal metal q124-e1-03.fm page 15 tuesday, may 30, 2006 5:22 pm
16 electromagnetic coupling rfid system v600 note: 1. when data carriers are flush-mounted in metal, the read/ write distance will depend on the distance (x) between the side of the dc and the metal surface. 2. use the following method for flush mounting into a metallic base. v600-d8kr04 (unsealed) v600-h07 stationary flush-mount- ed in metal irrelevant see note1. the listed transmission distances also apply for installation on non- metallic surfaces. refer to the v600 r/w heads and sram data carri- ers operation manual (cat. no. z127) for details. surface- mounted on metal 10 to 100 mm (max. axial offset 10 mm) moving flush-mount- ed in metal see note1. surface- mounted on metal 50 to 100 mm (max. axial offset 10 mm) v600-h11 stationary flush-mount- ed in metal irrelevant see note1. surface- mounted on metal 10 to 65 mm (max. axi- al offset 10 mm) moving flush-mount- ed in metal see note1. surface- mounted on metal 30 to 65 mm (max. axi- al offset 10 mm) v600-d8kf04 v600-h07 stationary flush-mount- ed in metal irrelevant see note1. surface- mounted on metal 10 to 50 mm (max. axi- al offset 10 mm) moving flush-mount- ed in metal see note1. surface- mounted on metal 25 to 50 mm (max. axi- al offset 10 mm) v600-h11 stationary flush-mount- ed in metal irrelevant see note1. surface- mounted on metal 10 to 32 mm (max. axi- al offset 10 mm) moving flush-mount- ed in metal see note1. surface- mounted on metal 15 to 32 mm (max. axi- al offset 10 mm) v600-d2kr16 v600-h11 stationary flush-mount- ed in metal irrelevant 2 to 15 mm (max. axial offset 10 mm) (see note 2.) surface- mounted on metal 2 to 15 mm (max. axial offset 10 mm) moving flush-mount- ed in metal 6 to 15 mm (max. axial offset 10 mm) (see note 2.) surface- mounted on metal 10 to 15 mm (max. axi- al offset 10 mm) recommended combinations installation controller mode transmission distance condition for dc and r/w head installation data carrier r/w head flush-mounted mm mm 20 mm max. metal refer to the v600 r/w heads and sram data carriers operation manual (cat. no. z127) for details. flush-mounted 10 mm min. 10 mm min. metal q124-e1-03.fm page 16 tuesday, may 30, 2006 5:22 pm
electromagnetic coupling rfid system v600 17 influence of surrounding metal v600-d8kr04 combined with v600-h07 v600-d8kf04 combined with v600-h07 v600-d8kr04 combined with v600-h11 v600-d8kf04 combined with v600-h11 transmission distance (mm) 100 50 0 20406080 (axial offset: 0 mm) distance from metal surface ( ) (mm) r/w head data carrier (above 100) 60 30 20 10 70 0 20406080100 40 50 transmission distance (mm) (axial offset: 0 mm) distance from metal surface ( ) (mm) r/w head data carrier (above 100) transmission distance (mm) 80 60 40 20 100 0 20406080 (axial offset: 0 mm) r/w head data carrier distance from metal surface ( ) (mm) (above 100) 0 20 40 60 80 100 20 30 40 50 60 10 70 transmission distance (mm) (axial offset: 0 mm) distance from metal surface ( ) (mm) r/w head data carrier (above 100) q124-e1-03.fm page 17 tuesday, may 30, 2006 5:22 pm
18 electromagnetic coupling rfid system v600 lower-level communications mode setting (distance/time priority) the lower-level communications mode is set with the dip switch or memory switch on the serial-interface controller (v600-ca5d02, v600-cd1d- v3, v600-cm1d) or id sensor unit. (refer to the controller?s operation manual for more details on the setting.) characteristic data (typical) transmission range note: the values shown in the following graphs are in millimeters. refer to pages 10 to 16 for details on data carrier and r/w head m ounting conditions. battery-less data carriers with small memory capacity v600-d23p71 & v600-h07 v600-d23p72 & v600-h07 v600-d23p66n & v600-h07 v600-d23p66sp & v600-h07 v600-d23p61 & v600-h11 v600-d23p71 & v600-h11 v600-d23p72 & v600-h11 v600-d23p66n & v600-h11 v600-d23p66sp & v600-h11 v600-d23p61 & v600-h51 0 ? 20 ? 40 ? 60 ? 80 ? 100 ? 120 20 40 60 80 100 120 20 40 60 80 100 y x x y 0 ? 20 ? 40 ? 60 ? 80 ? 100 ? 120 20 40 60 80 100 120 20 40 60 80 100 y x x y 0 ? 20 ? 40 ? 60 ? 80 ? 100 20 40 60 80 100 20 40 60 80 y x x y 0 ? 20 ? 40 ? 60 ? 80 ? 100 20 40 60 80 100 20 40 60 80 y x x y 0 ? 10 ? 20 ? 30 ? 40 ? 50 10 20 30 5040 10 20 30 40 y x x y 0 ?20?40?60?80?100 20 40 60 80 100 20 40 60 80 y x x y 0 ?20 ?40 ?60 ?80 20 40 60 80 20 40 60 y x x y 0 ? 20 ? 40 ? 60 ? 80 20 40 60 80 20 40 60 y x x y 0 ? 20 ? 40 ? 60 ? 80 20 40 60 80 20 40 60 x y x y 0 ? 10 ? 20 ? 30 ? 40 10 20 30 40 10 20 30 y x y x read range (in transmission distance priority mode) write range (in transmission distance or transmission time priority mode) read ran g e ( in transmission time p riorit y mode ) q124-e1-03.fm page 18 tuesday, may 30, 2006 5:22 pm
electromagnetic coupling rfid system v600 19 0 ? 5 ? 10 5 10 5 10 y y x x x 0 ? 5 ? 10 5 10 5 10 y x y x 0 ? 5 ? 10 5 10 5 10 y x y x 0 ? 5 ? 10 ? 15 5 15 10 5 1510 y x y x 0 ? 5 ? 10 ? 15 5 15 10 5 1510 y y x x 0 ? 5 ? 10 ? 15 5 15 10 5 1510 x y y x 0 ? 5 ? 10 ? 15 5 10 15 5 10 15 y x y x 0 ? 5 ? 10 ? 15 5 15 10 5 10 15 y x y x 0 ? 5 ? 10 ? 15 5 15 10 5 10 15 x y y x v600-d23p53 & v600-hs51 +v600-ha51 v600-d23p53 & v600-hs61 +v600-ha51 v600-d23p53 & v600-h52 v600-d23p54 & v600-hs51 +v600-ha51 v600-d23p54 & v600-hs61 +v600-ha51 v600-d23p54 & v600-h52 v600-d23p55 & v600-hs51 +v600-ha51 v600-d23p55 & v600-hs61 +v600-ha51 v600-d23p55 & v600-h52 read range (in transmission distance priority mode) write range (in transmission distance or transmission time priority mode) read ran g e ( in transmission time p riorit y mode ) q124-e1-03.fm page 19 tuesday, may 30, 2006 5:22 pm
20 electromagnetic coupling rfid system v600 built-in-battery data carriers with large memory capacity v600-d8kr12 & v600-h07 v600-d8kr13 & v600-h07 v600-d8kr04 & v600-h07 v600-d8kr12 & v600-h11 v600-d8kr13 & v600-h11 v600-d8kr04 & v600-h11 battery-less data carriers with large memory capacity v600-d8kf04 & v600-h07 v600-d8kf04 & v600-h11 replaceable-battery data carriers with large memory capacity v600-d2kr16 & v600-h11 0 ?20?40?60?80?100 20 40 60 80 100 20 40 60 80 x y x y 0 ? 20 ? 40 ? 60 ? 80 ? 100 20 40 60 80 100 20 40 60 80 x y x y 0 ? 40 ? 80 ? 120 ? 160 40 80 120 160 40 80 120 x y x y 0 ? 20 ? 40 ? 60 ? 80 20 40 60 80 20 40 60 x y x y 0 ? 20 ? 40 ? 60 ? 80 20 40 60 80 20 40 60 x y x y 0 ? 20 ? 40 ? 60 ? 80 ? 100 20 40 60 80 100 20 40 60 80 x y x y 0 ? 20 ? 40 ? 60 ? 80 ? 100 20 40 60 80 100 20 40 60 80 x y x y 0 ? 20 ? 40 ? 60 ? 80 ? 100 20 40 60 80 100 20 40 60 80 x y x y 0 ? 20 ? 40 ? 60 ? 80 20 40 60 80 20 40 60 x y x y read/write range (in transmission distance or transmission time priority mode) q124-e1-03.fm page 20 tuesday, may 30, 2006 5:22 pm
electromagnetic coupling rfid system v600 21 communications time ? the communications time does not depend on the model of r/w head or data carrier, although communications times differ between data carriers with and without batteries.  the turn around time (tat) is the total time required from the issu- ance of a command from the host device (for example, a host com- puter) until the reception of a response.  the lower-level communications time does not include the host communications; it is the time required for communications between the r/w head and data carrier. the lower-level commu- nications time is used in the equation for the dc speed. dc speed = (distance travelled in the transmission range)/ (lower-level communications time) lower-level communications time with built-in-battery data carriers (reference) calculation (reference) n is the number of processing bytes. v600-d8kf04 (battery-less) calculation (reference) n is the number of processing bytes. lower-level communications time with battery-less data carriers (reference) (battery-less models excluding v600- d8kf04) calculation (reference) n is the number of processing bytes. tat (turn around time) lower-level communications time command response rd001122* rdh1* lower-level communications time (ms) read t = 1.8 n + 48.4 write t = 4.2 n + 86.5 lower-level communications time (ms) read t = 1.8 n + 168.4 write t = 4.2 n + 206.5 1,000 800 600 400 200 0 1 50 100 150 200 250 300 number of byte s lower-level communication time (ms) (auto) read (auto) write 1,000 800 600 400 200 0 1 50 100 150 200 250 300 number of b y te s lower-level communication time (ms) (auto)read (auto)write r/w lower-level communications time (ms) distance priority mode read t = 4.3 n + 64.6 write t = 8.7 n + 167.1 time priority mode read t = 1.8 n + 79.0 write t = 7.1 n + 180.4 2,500 2,000 1,500 1,000 500 0 50 100 150 200 250 300 number of bytes lower-level communication time (ms) (auto) read (auto) write transmission distance priority mode transmission time priority mode q124-e1-03.fm page 21 tuesday, may 30, 2006 5:22 pm
22 electromagnetic coupling rfid system v600 battery life the data carrier has a built-in lithium battery. the following graphs show the relationship between the number of bytes per transmission, the number of transmissions per day, a nd the battery life. temperature and battery life v600-d2kr16 the battery life is two years at 25 c regardless of the relationship between the number of bytes read/written and the number of transmissions. examples showing relationship between battery life and temperature the following table shows the standard values. note: if the battery is stored at 70 c and is not installed, the battery life is calculated as follows: 2 (years) (1 - 0.32) = 1.36 years if the battery is stored at 25 c after one year?s storage, the bat- tery life will be approximately 1 year and 4 months. (the battery life will be shortened if the battery is used at temperatures close to 0 c or 50 c.) the values in the above graph are based on the battery being installed (i.e., the insulation sheet is removed). if the battery is not installed, the values shown in the above table will apply. v600-d8kr12 (typical example) v600-d8kr04 (typical example) v600-d8kr13 (typical example) number of bytes/transmission daily number of transmissions x 100 8 years 5 years number of bytes/transmission daily number of transmissions x 100 8 years 5 years number of bytes/transmission daily number of transmissions x 100 8 years 5 years 2.5 2 1.5 1 0.5 01020304050 ambient tem p erature ( ? c ) battery life (years) temperature battery consumption rate in one year 20 c1 % 30 c2 % 40 c4 % 50 c8 % 60 c 16% 70 c 32% q124-e1-03.fm page 22 tuesday, may 30, 2006 5:22 pm
electromagnetic coupling rfid system v600 23 precautions data carrier batteries built-in-battery data carriers replaceable-battery data carriers mutual interference (reference values) mutual interference between r/w heads when more than one set of r/w heads are used, mutual interference between the heads can be avoided by mounting the heads at the specified distance as shown below. v600-h07  facing rd/wt command: 650 mm min. auto command: 900 mm min.  side-by-side rd/wt command: 550 mm min. auto command: 1,200 mm min. v600-h11  facing rd/wt command: 200 mm min. auto command: 200 mm min.  side-by-side rd/wt command: 200 mm min. auto command: 200 mm min. warning the sram-type data carrier has a built-in lithium battery which may occasionally ignite, explode, and burn if mishandled. do not disassemble, deform, heat above 212 f (100 c), or incinerate the data carrier. warning the sram-type data carrier has replaceable lithium batteries which may occasionally take fire, explode, burn, or leak liquid if mishandled. do not deform, heat above 212 f (100 c), incinerate, or charge the batteries, or short-circuit their positive and negative terminals. 650 mm min. ( 900 mm min. ) 550 mm min. (1,200 mm min.) 200 mm min. 200 mm min. q124-e1-03.fm page 23 tuesday, may 30, 2006 5:22 pm
24 electromagnetic coupling rfid system v600 v600-hs61  facing: 80 mm min.  side-by-side: 80 mm min. v600-hs61 v600-hs61 note: if the two r/w heads are not transmitting simultaneously (i.e., independent read/write), mutual interference will not occur. th erefore, the restriction on the distance between the heads will not be applicable. the commands will be received by the r/w heads and transmission will oscillate between them. mutual interference between proximity sensors the v600-series units use electromagnetic coupling (frequency: 530 khz). when a v600 unit is wired close to r/w heads, proximit y switches, and sensors that have an oscillating frequency between 400 and 600 khz, the proximity sensor may malfunction, so be sure to ins tall the units according to the distance restrictions specified in the following diagrams. make sure to thoroughly test that the mounting posi tions and the fixed positions of the sensors are correct before putting them into actual operation. v600-h07  vertical/parallel: 400 mm min.  facing: 300 mm min. 120 mm min. 80 mm min. 80 mm min. v600-hs51 v600-hs51 v600-h51 ? facing: 120 mm min. v600-h52 ? facing: 80 mm min. ? side-by-side: 80 mm min. v600-hs51 ? facing: 80 mm min. ? side-by-side: 80 mm min. 100 mm min. 80 mm min. 80 mm min. v600-hs51 v600-hs51 ? side-by-side: 100 mm min. v600-h51 v600-h51 v600-h52 v600-h52 v600-h51 v600-h51 v600-h52 v600-h52 80 mm min. v600 -hs61 v600 -hs61 80 mm min. 400 mm min. 400 mm min. proximity sensor proximity sensor v600-h07 300 mm min. proximity sensor v600-h0 7 q124-e1-03.fm page 24 tuesday, may 30, 2006 5:22 pm
electromagnetic coupling rfid system v600 25 v600-h11  vertical/parallel: 100 mm min.  facing: 100 mm min. 100 mm min. 100 mm min. proximity sensor proximity sensor v600-h11 100 mm min. proximity sensor v600-h11 100 mm min. 200 mm min. 150 mm min. v600-h51/52 proximity sensor proximity sensor proximity sensor 100 mm min. 150 mm min. v600-hs51 proximity sensor proximity sensor proximity sensor 100 mm min. 100 mm min. 100 mm min. v600-hs61 v600-hs61 proximity sensor proximity sensor proximity sensor v600-h51/h52 v600-hs51 v600-hs61 200 mm min. q124-e1-03.fm page 25 tuesday, may 30, 2006 5:22 pm
26 electromagnetic coupling rfid system v600 mutual interference between data carriers when more than one data carrier is used, mutual interference between the dcs can be avoided by making sure that they are mounte d apart at the distances specified below. reading/writing v600-d23p53 r/w head: v600-h52, v600-hs51 + v600-ha51, v600-hs61 + v600-ha51 v600-d23p55 r/w head: v600-h52, v600-hs51 + v600-ha51, v600-hs61 + v600-ha51 v600-d23p66n r/w head: v600-h11 r/w head: v600-h07 v600-d23p54 r/w head: v600-h52, v600-hs51 + v600-ha51, v600-hs61 + v600-ha51 v600-d23p61 r/w head: v600-h11/-h51 v600-d23p66sp r/w head: v600-h11 r/w head: 600-h07 v600-d23p72 r/w head: v600-h11 r/w head: v600-h07 v600-d23p71 r/w head: v600-h07 40 mm min. 50 mm min. 140 mm min. 160 mm min. 45 mm min. 90 mm min. 140 mm min. 160 mm min. 170 mm min. 140 mm min. 210 mm min. 180 mm min. 290 mm min. 210 mm min. q124-e1-03.fm page 26 tuesday, may 30, 2006 5:22 pm
electromagnetic coupling rfid system v600 27 v600-d8kr12 r/w head: v600-h11 r/w head: v600-h07 v600-d8kr13 r/w head: v600-h11 r/w head: v600-h07 v600-d8kr04/v600-d8kf04 r/w head: v600-h11 v600-d2kr16 r/w head: v600-h11 r/w head: v600-h07 140 mm min. 140 mm min. 160 mm min. 160 mm min. 160 mm min. 160 mm min. 180 mm min. 160 mm min. 180 mm min. 180 mm min. 150 mm min. 90 mm min. 220 mm min. q124-e1-03.fm page 27 tuesday, may 30, 2006 5:22 pm
28 electromagnetic coupling rfid system v600 dimensions note: all units are in millimeters unless otherwise indicated. data carriers with large memory capacity built-in-battery dcs v600-d8kr12 v600-d8kr04 replaceable-battery dcs v600-d2kr16 battery-less dcs v600-d8kf04 v600-d8kr13 40 30 0.2 10 65 55 0.2 5 27 10 two, 4.5-dia. mounting holes 15 8 case: abs resin filler: epoxy resin 54 20 44 0.2 10 86 31 four, 4.5-dia. mounting holes 5 5 76 0.2 case: abs resin filler: epoxy resin 65 4-r1.5 40 5 r0.5 case: abs resin 54 20 44 0.2 10 86 31 four, 4.5-dia. mounting holes 5 5 76 0.2 case: abs resin filler: epoxy resin 86 27 two, 4.5-dia. mounting holes 10 54 440.2 10.3 5 5 760.2 10 case: abs resin filler: epoxy resin q124-e1-03.fm page 28 tuesday, may 30, 2006 5:22 pm
electromagnetic coupling rfid system v600 29 data carriers with small memory capacity battery-less dcs v600-d23p66n v600-d23p66sp v600-d23p71 v600-d23p72 5 0 ? 0.1 6 0 ? 0.2 5 0 ? 0.1 24 2.2 6 36 30 0.1 24 r0.2 8 0 ? 0.1 dia. 2-r1.0 r0.3 12 0 ? 0.2 dia. r0.2 8 0 ? 0.1 dia. two, 3.5-dia. mounting holes v600-d23p53 v600-d23p54 v600-d23p55 v600-d23p61 case: abs resin filler: epoxy resin case: abs resin filler: epoxy resin case: pps resin filler: epoxy resin case: abs resin filler: epoxy resin 4-r4 32 34 25 0.2 4-r3 32 34 25 0.2 two, 6-dia. 3.5 0.1 two, 3.5-dia. 25 0.2 25 0.2 2-m3 case: pps resin mounting hole dimensions 2-m5 4-r6 6.5 2.5 max. 34 36.5 34 80 0.2 95 1.3 80 0.2 mounting hole dimensions coating: pfa resin two, 5.5-dia. mounting holes 54 1.5 86 4-r2 case: glass epoxy resin coating: polyurethane resin 50 4-r2 34 1.5 case: glass epoxy resin coating: polyurethane resin q124-e1-03.fm page 29 tuesday, may 30, 2006 5:22 pm
30 electromagnetic coupling rfid system v600 r/w heads v600-h07 v600-h11 v600-h51 v600-hs51 (sensor section) v600-h52 v600-hs61 (sensor section) 50 5 5 100 90 0.2 four, 4.5-dia. mounting holes 100 90 0.2 50 14 power indicator (green) transmission indicators (orange) 10 10 25 43 connector 14.7 dia. bushing vinyl-insulated round cord (6-mm dia.) 30 20 11 case: abs resin filler: epoxy resin cable: pvc (oil-resistant) 23 11 5 power (green)/transmission (orange) indicators 5 4-r1 40 28 2-r5 two, 4.5-dia. mounting holes 10 bushing 14.7 dia. 43 vinyl-insulated round cord (6-mm dia.) connector 27 53 6 20 18 135 accessories: two brackets for rear panel mounting case: abs resin filler: epoxy resin cable: pvc (oil-resistant) 19.8 dia. 7 62.5 m22x1 2 lock washers 2 lock nuts power (green)/transmission (orange) indicators vinyl-insulated round cord (6-mm dia.) connector (66) (72) 80 43 14.7 dia. case: brass transmission window: abs resin filler: epoxy resin cable: pvc (oil-resistant) 33 35 49.5 7 m12x1 2 lock washers 2 lock nuts vinyl-insulated round cord (4-mm dia.) connector 9.6 dia. 13.7 dia. case: brass transmission window: abs resin filler: epoxy resin cable: pvc (oil-resistant) 12 dia. 12 67.5 m22x1 2 lock washers 2 lock nuts power (green)/transmission (orange) indicators vinyl-insulated round cord (6-mm dia.) connector (71) (77) 85 43 14.7 dia. case: brass transmission window: abs resin filler: epoxy resin cable: pvc (oil-resistant) 30.5 18 4.5 8.5 12 0.1 49.5 18 10 13.7 dia. transmission surface connector vinyl-insulated round cord (4-mm dia.) 6.5 two, 3.5x5 mounting holes case: abs resin filler: epoxy resin cable: pvc (oil-resistant) q124-e1-03.fm page 30 tuesday, may 30, 2006 5:22 pm
electromagnetic coupling rfid system v600 31 v600-ha51 (amplifier section) id controllers 22.6 36.5 23.5 8 6.1 vinyl-insulated round cord 6-mm dia (7/0.18-mm dia.), 8-conductor cable connector 14.7 dia. 35.6 13.2 two, 4.5-dia. mounting holes 51.3 0.2 4 13.7 dia. 22 51.7 61.8 5.9 5 12.8 dia. (10,000) 43 power indicator (green) connector operating indicator (orange) case: abs resin filler: epoxy resin cable: pvc (oil-resistant) open 5.5 53 81 92 115 80 50 17.5 18 68 76 78 92 102 21.5 9 6 5 57.4 86.3 95 107 16.5 v600-ca5d02 (compact) v600-cd1d-v3 (compact) two, 4.5-dia. four, 3.5-dia. r/w head connector v600-cm1d (board-mounted) 90 80 105 95 5 5 7.5 80 65 18 17.5 two, 4.5-dia. mounting holes q124-e1-03.fm page 31 tuesday, may 30, 2006 5:22 pm
32 electromagnetic coupling rfid system v600 accessories holder v600-a81 v600-a84 attachment v600-a86 9 3.5 2-r2.5 20 42 24 0.1 68 40 0.1 (four, 3.5-dia.) (four, 5.5-dia.) 8-r0.5 case: abs resin 2.1 95.6 2.1 4-r3 24.4 99.8 0.5 42.5 2.1 63.6 2.1 8.5 5 67.8 0.5 use m3 countersunk screws in the two 3.2-dia. mounting holes or apply ultrasonic welding. 25 0.2 25 0.2 25 0.2 25 0.2 15 34 37 15 34 37 16 4 10 3.5 two, 4-dia. 4-r5.5 2-m3 material: pps resin mounting hole dimensions all dimensions shown are in millimeters. to convert millimeters into inches, multiply by 0.03937. to convert grams into ounces, multiply by 0.03527. q124-e1-03.fm page 32 tuesday, may 30, 2006 5:22 pm
r ead and u nderstand this document please read and understand this document before using the products. please consult your omron representative if you have any qu estions or comments. warranty omron?s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by omron. omron makes no warranty or representation, express or implied, regarding non-infringement, merchantability, or fitness for particular purpose of the products. any buyer or user acknowledges that the buyer or user alone has determined that the products will suitably meet the requirements of their intended use. omron disclaims all other warranties, express or implied. limitations of liability omron shall not be responsible for special, indirect, or consequential damages, loss of profits or commercial loss in any way connected with the products, whether such claim is based on contract, warranty, negligence, or strict liability. in no event shall responsibility of omron for any act exceed t he individual price of the product on which liability is asserted . in no event shall omron be responsible for warranty, repair, or other claims regarding the products unless omron?s analysis confirms that the products were properly handled, stored, installed, and maintained and not subject to contamination, abuse, misuse, or inappropriate modification or repair. suitability for use the products contained in this document are not safety rated. they are not designed or rated for ensuring safety of persons, and should not be relied upon as a safety component or protective device for such purposes. please refer to separate catalogs for omron's safety rated products. omron shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of produc ts in the customer?s application or use of the product. at the customer?s request, omron will provide applicable third party certification documents identifying ratings and limitation s of use that apply to the products. this information by itself is not sufficient for a complete determin ation of the suitability of the products in combination with the end product, machine, system, or other application or use. the following are some examples of applications for which particular attention must be given. this is not intended to be an exh austive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:  outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described i n this document.  nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations.  systems, machines, and equipment that could present a risk to life or property. please know and observe all prohibitions of use applicable to the products. never use the products for an application involving serious risk to life or property without ensuring that the system as a whole has been designed to address the risks, and that the omron product is properly rated and installed for the intended use within the overall equipment or system. performance data performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. it may represent the result of omron?s test conditions, and the users must correlate it to act ual application requirements. actual performance is subject to t he omron warranty and limitations of liability. change in specifications product specifications and accessories may be changed at any time based on improvements and other reasons. it is our practice to change model numbers when published ratings or features are changed, or when significant construction cha nges are made. however, some specifications of the product may be changed without any notice. when in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. please consult with your omron repr esentative at any time to confirm actual specifications of purc hased products. dimensions and weights dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. errors and omissions the information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assum ed for clerical, typographical, or proofreading errors, or omissions. programmable products omron shall not be responsible for the user?s programming of a programmable product, or any consequence thereof. copyright and copy permission this document shall not be copied for sales or promotions without permission. this document is protected by copyright and is intended solely for use in conjunction with the product. please notify us before copying or reproducing this document in any manner, for any other purpose. if copying or transmitting th is document to another, please copy or transmit it in its entir ety. q124-e1-03.fm page 36 tuesday, may 30, 2006 5:22 pm
2007. 3 omron corporation industrial automation company http://www.ia.omron.com/ (c)copyright omron corporation 2007 all rights reserved. in the interest of product improvement, specifications are subject to change without notice. cat. no. q124-e1-03


▲Up To Search▲   

 
Price & Availability of V600-A44

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X